Datacenter Location Profiles
Downtown, Seattle, WA |
![]() |
Facility |
|
• 22,000 sq. ft. facility |
• TXU fault tolerant electrical grid |
• 18,000 sq. ft. of raised floor |
• 2000 amps of 480v input power |
• 2 Data Air AC Units |
• 1 main transfer switch |
• Over 150 smoke detectors |
• 2 500KVA Powerware UPS units |
• security badge entry/exit on all doors |
• Standalone PDUs at each cabinet row |
• DataTrax monitoring software |
• 1 megawatt generator |
Network |
|
• Cisco Certified Network |
• OC48 - MCI |
• Cisco 6500 Series Routing & Switches |
• OC48 - Level 3 |
• Linux Fedora 3, & Debian OSs |
• 1Gbps Direct Fiber - Level 3 |
• Windows 2003 Server OSs |
|
Downtown, San Francisco, CA |
![]() |
Facility |
|
• 40,000 sq. ft. facility |
• 3000 amps of 480v input power |
• 40,000 sq. ft. of raised floor |
• 1 main transfer switch |
• 15, 25 ton Delta AC Units |
• 12 500KVA Powerware UPS units |
• Over 800 smoke detectors |
• Standalone PDUs at each cabinet row |
• security badge entry/exit on all doors |
• 1megawatt generator |
Network |
|
• Cisco Certified Network |
• OC48 - SBC |
• Cisco 6500 Series Routing & Switches |
• 1Gbps Direct Fiber - Level 3 |
• Linux Fedora 3, & Debian OSs |
• Windows 2003 Server OSs |
Downtown, Dallas, TX |
![]() |
Facility |
|
• 60,000 sq. ft. facility |
• 4800 amps of 480v input power |
• 50,000 sq. ft. of raised floor |
• 3 main transfer switches |
• 21, 26 ton Data Air AC units |
• 6, 500KVA Powerware UPS units |
• Over 500 smoke detectors |
• Standalone PDUs at each cabinet row |
• Multiple TXU electrical grids |
• 1.5 megawatt generator |
• security badge entry/exit on all doors |
• DataTrax monitoring software |
Network |
|
• Cisco Certified Network |
• OC48 - SBC |
• Cisco 6500 Series Routing & Switches |
• OC48 - Time Warner |
• Linux Red Hat Enterprise, Fedora 3, & Debian OSs |
• OC48 - MCI |
Downtown, Orlando, FL |
![]() |
Facility |
|
• 40,000 sq. ft. facility |
• 2000 amps of 480v input power |
• 40,000 sq. ft. of raised floor |
• 1 main transfer switch |
• 14, 25 ton Delta AC Units |
• 10 500KVA Powerware UPS units |
• Over 700 smoke detectors |
• Standalone PDUs at each cabinet row |
• security badge entry/exit on all doors |
• 1megawatt generator |
Network |
|
• Cisco Certified Network |
• OC48 - Time Warner |
• Cisco 6500 Series Routing & Switches |
• OC48 - MCI |
• Linux Red Hat Enterprise, Fedora 3 OSs |
• OC48 - Looking Glass |
The Servers
oneilonline utilizes both AMD and Intel hardware to make sure that we provide the best possible hosting solution. The following is the standard hardware configuration, and what the servers look like: